MIL-DTL-11352K(AT)
Tolerance limits
1.15A
Sine wave translated
A
down to 0.15A
0.85A
Sine wave translated
up to 0.15A
Ideal sine wave
0.2A
0.05A
0.2A
Reference
line zero
0.05A
0.3A
0.2A
0.3D
D
A = Peak value = 30 g
D = Nominal duration = 11 ms
NOTE:
The oscillogram shall include a time about 3D long with a pulse located approximately
in the center. The acceleration amplitude of the ideal half sine pulse is A and its
duration is D. The measured acceleration pulse shall be contained between the broken
line boundaries and the measured velocity change (which may be obtained by
integration of the acceleration pulse) shall be within the limits of Vi + 0.1Vi, where Vi
is the velocity-change associated with the ideal pulse, which equals 2AD/. The
integration to determine velocity change shall extend from 0.4D before the pulse to
0.1D after the pulse.
FIGURE 2. Half-sine shock pulse configuration and tolerance limits.
18
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business